WHAT IS “PACKTEST”
WHAT IS “PACKTEST”
WHERE PACKTEST IS USED
STORY BEHIND THE DEVELOPMENT OF PACKTEST
PRODUCTS
NEWS
ABOUT US
COMPANY PROFILE
HISTORY
OVERSEA DEALER
LANGUAGE
日本語
English
中文(简体)
CONTACT US
TREND KEYWORD
COD
BOD
Chromium
Copper
Search by
Place
Factory
School (Educational Material)
Building Maintenance
Household
Outdoor (Rivers)
Pool
Spa/Public Hot Tubs
Medical
Search by
Purpose
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Soil Contamination Countermeasures
Investigation for Abnormality
Health and Safety (Disinfectant)
Search by
Inspection item
Zinc
Sulfite
Alkalinity (Acidic Consumption)
Aluminum
Chloride
Chlorine
Ozone
Surfactant
Hydrogen Peroxide
Potassium Permanganate Consumption
Calcium
Gold
Silver
Metals
Glucose
Chromium
Hardness
Free Cyanide
COD
Color
Silica
Turbidity
Nitrogen
Iron
Copper
Lead
Nickel
pH
BOD (Biochemical Oxygen Demand)
Arsenic
Vitamin C (L-Ascorbic Acid)
Hydrazine
Phenol
Fluoride
Boron
Formaldehyde
Magnesium
Manganese
Molybdenum
Oil
Sulfide
Sulfate
Phosphate
Product List
PRODUCTS
SCROLL
LANGUAGE
日本語
English
中文(简体)
HOME
Products
PACKTEST Nickel (DPM)
Wastewater Management
Process Management/Quality Control
Model
WAK-Ni(D)
Range
0.3, 0.5, 1, 2, 5, 10 mg/L
Quantity
(pcs./box)
50
PACKTEST Nitrite
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-NO2
Range
0.02, 0.05, 0.1, 0.2, 0.5, 1 mg/L
0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5 mg/L
Quantity
(pcs./box)
50
PACKTEST Nitrite (High Range)
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-NO2(C)
Range
16, 33, 66, 160, 330, ≥660 mg/L
5, 10, 20, 50, 100, ≥200 mg/L
Quantity
(pcs./box)
50
PACKTEST Nitrate
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-NO3
Range
1, 2, 5, 10, 20, 45 mg/L
0.2, 0.5, 1, 2, 5, 10 mg/L
Quantity
(pcs./box)
50
PACKTEST Nitrate (High Range)
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-NO3(C)
Range
90, 225, 450, 900, 2250, 4500 mg/L
20, 50, 100, 200, 500, 1000 mg/L
Quantity
(pcs./box)
50
PACKTEST Ozone
Process Management/Quality Control
Health and Safety (Disinfectant)
Model
WAK-O3
Range
0.1, 0.2, 0.5, 1, 2, 5 mg/L
Quantity
(pcs./box)
50
PACKTEST P-Alkalinity
Process Management/Quality Control
Facility Maintenance
Environmental Research
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-PAL
Range
0, 100, 200, 300, 400, 500, 600 CaCO
3
mg/L
Quantity
(pcs./box)
50
PACKTEST pH
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-pH
Range
pH 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5
Quantity
(pcs./box)
50
PACKTEST PMD (Potassium Permanganate Consumption)
Process Management/Quality Control
Facility Maintenance
Model
WAK-PMD-2
Range
0, 3, 6, 10, 12, 15 mg/L
Quantity
(pcs./box)
50
PACKTEST Phenol
Wastewater Management
Drinking Water Inspection
Investigation for Abnormality
Model
WAK-PNL
Range
0, 0.2, 0.5, 1, 2, 5, 10 mg/L
Quantity
(pcs./box)
40
PACKTEST Phosphate (High Range)
Wastewater Management
Process Management/Quality Control
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Model
WAK-PO4(C)
Range
2, 5, 10, 20, 50, 100 mg/L
0.66, 1.65, 3.3, 6.6, 16.5, 33 mg/L
Quantity
(pcs./box)
40
PACKTEST Phosphate (Low Range)
Wastewater Management
Process Management/Quality Control
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Model
WAK-PO4(D)
Range
0.05, 0.1, 0.2, 0.5, 1, 2 mg/L
0.02, 0.05, 0.1, 0.2, 0.5, 1 mg/L
Quantity
(pcs./box)
40
PACKTEST Sulfide (Hydrogen Sulfide)
Environmental Research
Model
WAK-S
Range
0.1, 0.2, 0.5, 1, 2, 5 mg/L
Quantity
(pcs./box)
40
PACKTEST Silica
Process Management/Quality Control
Facility Maintenance
Model
WAK-SiO2
Range
5, 10, 20, 50, 100, 200 mg/L
Quantity
(pcs./box)
40
PACKTEST Silica (Low Range)
Process Management/Quality Control
Facility Maintenance
Model
WAK-SiO2(D)
Range
0.5, 1, 2, 5, 10, 20 mg/L
Quantity
(pcs./box)
40
PACKTEST Sulfite (High Range)
Process Management/Quality Control
Facility Maintenance
Model
WAK-SO3(C)
Range
50, 100, 200, 500, 1000, 2000 mg/L
Quantity
(pcs./box)
50
PACKTEST Sulfate (High Range)
Process Management/Quality Control
Facility Maintenance
Environmental Research
Model
WAK-SO4(C)
Range
50, 100, 200, 500, 1000, ≥2000 mg/L
Quantity
(pcs./box)
40
PACKTEST Total Residual Chlorine
Process Management/Quality Control
Drinking Water Inspection
Educational Material
Agriculture (Fertilizer)
Investigation for Abnormality
Health and Safety (Disinfectant)
Model
WAK-T-ClO
Range
0.1, 0.2, 0.4, 1, 2, 5 mg/L
Quantity
(pcs./box)
50
PACKTEST Total Hardness
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Model
WAK-TH
Range
0, 10, 20, 50, 100, 200 mg/L
Quantity
(pcs./box)
50
PACKTEST Total Nitrogen (Inorganic)
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Investigation for Abnormality
Model
WAK-TN-i-3
Range
0, 5, 10, 25, 50, 100 mg/L
Quantity
(pcs./box)
40
PACKTEST Vitamin C (L-Ascorbic Acid)
Educational Material
Model
WAK-VC-2
Range
0.1, 0.2, 0.5, 1, 2, ≥4 mg/100mL
1, 2, 5, 10, 20, ≥40 mg/L
Quantity
(pcs./box)
40
PACKTEST Zinc
Wastewater Management
Process Management/Quality Control
Drinking Water Inspection
Environmental Research
Investigation for Abnormality
Model
WAK-Zn
Range
0, 0.2, 0.5, 1, 2, ≥5 mg/L
Quantity
(pcs./box)
50
PACKTEST Zinc (Low Range)
Wastewater Management
Process Management/Quality Control
Drinking Water Inspection
Environmental Research
Investigation for Abnormality
Model
WAK-Zn(D)
Range
0, 0.05, 0.1, 0.2, 0.5, 1, ≥2 mg/L
Quantity
(pcs./box)
40
DIGITALPACKTEST-MULTI SP
Wastewater Management
Process Management/Quality Control
Facility Maintenance
Drinking Water Inspection
Environmental Research
Educational Material
Fish Farm (Aquarium)
Agriculture (Fertilizer)
Soil Contamination Countermeasures
Investigation for Abnormality
Health and Safety (Disinfectant)
Model
DPM-MTSP
Quantity
(pcs./box)
1
Pretreatment Reagent for Total Chromium
Model
Cr-RA
Quantity
(pcs./box)
approx.100 tests
Pretreatment Reagent for Nitrate
Model
NO3-RA
Quantity
(pcs./box)
50
PACKTEST Lead
Wastewater Management
Process Management/Quality Control
Drinking Water Inspection
Soil Contamination Countermeasures
Investigation for Abnormality
Model
SPK-Pb
Range
0, 0.05, 0.1, 0.2, 0.5, 1 mg/L
Quantity
(pcs./box)
20
PACKTEST Square Cup
Model
WAK-CC10
入数
10
最初
前の28件へ
2/ 2
次の28件へ
最後
2/ 2
HOME
TOP